- Home
- ยป
- Our Services
- »
- Material Testing Services
Material Testing Services
Seawater Acidified Test (SWAAT)
| Location/City | Pan India |
| Testing Type | ASTM |
| Technique | ASTM |
| Usage/Application | AutoMotive |
| Industry Body Standards | ASTM B 368-21 |
| Accredition | ISO 17025:2017 |
Mett-Bio Metallurgical Testing & Services with its state of the art equipment setup consisting of Salt Spray Chamber Complying to the Requirement of ASTM B368-2021 / ISO 9277:2017
Tests are performed in our ISO 17025:2005 NABL accredited lab under the standard Specified conditions or as per specific field conditions.
Copper Accelerated Acetic Acid Salt Spray is a test method where in a product or coatings resistance to corrosion is evaluated in severe corrosive conditions with extended exposure to a saline or salted spray
This testing is carried out in a closed chamber which is filled fog. The test specimen is exposed to a predetermined time period and inspected during its exposure. This test is carried out to check the integrity of coatings, paints in a corrosive environment. This test is carried out as per ASTM B117-19, ISO 9227:2017, IS 9844-1981..
Additional Information:
- Production Capacity: 250
- Delivery Time: As per Test Schedule
Half Cell Potential Testing Services
View Brochure
| Service Location | Laboratory / On Field |
| Test Standard | ASTM C876-22b |
| Accreditation | ISO 17025:2017 NABL |
| Applicable Material | Uncoated Reinforcing Steel in Concrete |
| Scope | This test method covers the estimation of the electrical corrosion potential of uncoated Steel bar |
The corrosion potential of aluminium alloys depends upon the quantity of certain elements present in the solid solution. The ASTM C876-22 test method calculates the corrosion potential of aluminium and its alloys in an aqueous solution of sodium chloride.
This test method can be deployed to determine the effectiveness of:
1.Solution heat treating and annealing
2.Extent of precipitation during artificial ageing and welding
3.Extent of diffusion of alloying elements from the core into the cladding of Alclad products
This test procedure includes the estimation of Corrosion potential of uncoated rebar and lab concrete at both onsite and Laboratory, to determine corrosion action of reinforcement steel. This test method can be used at any time during the lifetime of a concrete item. This test procedure is applicable regardless of members their size or the concrete cover of the reinforcement rebar. The results obtained using this test method should not be considered as a means of estimating the structural properties of the steel or reinforced concrete element.
Potential measurements are interpreted by our trained engineers or technicians with experience in: concrete materials and corrosion tests. Often it is necessary to use other data such as chloride content, depth of carbonation, results of the delamination study, the results of the corrosion rate and environmental exposure conditions, as well as measurements of the corrosion potential, to formulate conclusions on this corrosion activity of the embedded steel and its likely effect on the useful life of a structure..
Additional Information:
- Production Capacity: 140
- Delivery Time: As Per Test Schedule
Ultrasonic Flaw Detection Non Destructive Test
| Brand | Mett-Bio |
| Country of Origin | Made in India |
| Test Method | NACE TM0106-2016 |
| Test Type | NACE |
Additional Information:
- Delivery Time: As Per Test Schedule